RED COMPACT 35 User's Guide

Browse online or download User's Guide for Wood stove RED COMPACT 35. RED COMPACT 35 User guide User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - COMPACT 35

INSTALLATION AND USER GUIDE ENtranslation of original instructionsPELLET BOILERCOMPACT 35

Page 2

82-INSTALLATION INSTRUCTIONSPRECAUTIONS REGARDING INSTALLATIONIMPORTANT!Product installation and assembly must be carried out by qualied personnel.Th

Page 3 - INTRODUCTION

92-INSTALLATION INSTRUCTIONSTechnical Dept. - All rights reserved - Reproduction is prohibitedPOSITIONING AND RESTRICTIONSIn the case of simultaneous

Page 4 - 1-WARNINGS AND WARRANTY TERMS

10min.3,5 metriAT(A)AP(B)2-INSTALLATION INSTRUCTIONSFOREWORDThis chapter on the Smoke Flue has been produced in reference to the prescriptions of Euro

Page 5

11ABCDEABCD15°EF2-INSTALLATION INSTRUCTIONSTechnical Dept. - All rights reserved - Reproduction is prohibitedTECHNICAL CHARACTERISTICSFlues serving a

Page 6

12ABCDE30°FABD60°ECFABCDE45°F2-INSTALLATION INSTRUCTIONSROOF AT 30°ROOF AT 45°ROOF AT 60°A = MIN. 1.30 metresB = DISTANCE > 1.50 metresC = DISTANCE

Page 7

13 2-INSTALLATION INSTRUCTIONSTechnical Dept. - All rights reserved - Reproduction is prohibitedDIMENSIONINGThe drop in pressure (draft) of a ue d

Page 8

14199234567892-INSTALLATION INSTRUCTIONSMAINTENANCEThe ue must be kept clean, since the deposit of soot or unburned oils reduces the cross-section re

Page 9

152-INSTALLATION INSTRUCTIONSTechnical Dept. - All rights reserved - Reproduction is prohibitedCONNECTION TO FLUEThe connection between the ue and th

Page 10 - 2-INSTALLATION INSTRUCTIONS

16TISIUBAPUIIC43D2IEVU1F2-INSTALLATION INSTRUCTIONSEXAMPLES OF CORRECT INSTALLATION1. Installation of Ø150mm ue with hole for the passage of the tube

Page 11

173-DRAWINGS AND TECHNICAL SPECIFICATIONSTechnical Dept. - All rights reserved - Reproduction is prohibitedDRAWINGS AND CHARACTERISTICSCOMPACT 35 HYDR

Page 12

IITABLE OF CONTENTSTABLE OF CONTENTS ...IIINTRODUCTION ...

Page 13

183-DRAWINGS AND TECHNICAL SPECIFICATIONSTECHNICAL CHARACTERISTICS COMPACT 35 HYDROProduct class (EN 303-5:2012) 5Nominal thermal power to rebox 34,5

Page 14

1901002003004005006000 500 1000 1500 2000AB3-DRAWINGS AND TECHNICAL SPECIFICATIONSTechnical Dept. - All rights reserved - Reproduction is prohibitedRe

Page 15

204-INSTALLATION AND ASSEMBLYPREPARATION AND UNPACKINGThe Compact boiler is supplied complete with all its electrical and mechanical components and fa

Page 16

214-INSTALLATION AND ASSEMBLYTechnical Dept. - All rights reserved - Reproduction is prohibitedThe end user is responsible for product storage, dispos

Page 17

224-INSTALLATION AND ASSEMBLYREQUIREMENTS FOR SYSTEM INSTALLATION• the minimum distance in front of the product to allow for cleaning, maintenance, e

Page 18

235-PLUMBING CONNECTIONTechnical Dept. - All rights reserved - Reproduction is prohibitedPLUMBING CONNECTIONIMPORTANT:The connections depend on the ty

Page 19 - DRAWINGS AND CHARACTERISTICS

245-PLUMBING CONNECTIONFILLING THE SYSTEMFill the system slowly to allow air bubbles to pass through the vent holes of the heating system. For closed

Page 20

255-PLUMBING CONNECTIONTechnical Dept. - All rights reserved - Reproduction is prohibitedTo ll the system, the hydraulic kit (optional) is tted with

Page 21 - B = Load (l/h)

266 - ELECTRICAL CONNECTIONSGENERAL PRECAUTIONSElectrical safety of the system is ensured only when it is properly connected to an ecient earthing sy

Page 22 - 4-INSTALLATION AND ASSEMBLY

277 - INITIAL START-UPTechnical Dept. - All rights reserved - Reproduction is prohibitedBEFORE START-UPGENERAL PRECAUTIONSRemove all components that c

Page 23

1INTRODUCTIONTechnical Dept. - All rights reserved - Reproduction is prohibitedDDear Customer, Our boilers are designed and built in compliance with t

Page 24

2817 - INITIAL START-UPThe boiler will be subject to expansion and contraction during the start-up and cooling phases, therefore slight creaking noise

Page 25 - 5-PLUMBING CONNECTION

297 - INITIAL START-UPTechnical Dept. - All rights reserved - Reproduction is prohibitedLOADING THE PELLETSPellets loading can be either manual or aut

Page 26

3072 3 461 58 - MENU ITEMS AND OPERATIONCONTROL PANEL DISPLAYMenu itemsKEY1. Boiler lighting/shutdown2. Scrolling of programming menu to decrease.3. M

Page 27

318 - MENU ITEMS AND OPERATIONTechnical Dept. - All rights reserved - Reproduction is prohibitedPROGRAMMED MODE SETTING (TIMER) - Main menuSetting the

Page 28 - 6 - ELECTRICAL CONNECTIONS

328 - MENU ITEMS AND OPERATIONNOTES FOR TIMER OPERATION• Start-up with the timer always takes place with the last temperature and ventilation setting

Page 29 - 7 - INITIAL START-UP

338 - MENU ITEMS AND OPERATIONTechnical Dept. - All rights reserved - Reproduction is prohibitedSETTINGS MENUThe SETTINGS menu allows to act on the bo

Page 30

348 - MENU ITEMS AND OPERATIONc - Feed screw loading Allows to ll the pellets loading system. It can only be activated with the boiler switched o, i

Page 31

358 - MENU ITEMS AND OPERATIONTechnical Dept. - All rights reserved - Reproduction is prohibitedg - Eco Shutdown tTo select the Eco - shutdown t funct

Page 32 - CONTROL PANEL DISPLAY

368 - MENU ITEMS AND OPERATIONi - Auxiliary boilerOne must install an additional module (optional) to enable start-up of an auxiliary boiler in the ev

Page 33

378 - MENU ITEMS AND OPERATIONTechnical Dept. - All rights reserved - Reproduction is prohibitedn - Maximum power (only for expert users)It allows to

Page 34

21-WARNINGS AND WARRANTY TERMS SAFETY PRECAUTIONS • Installation, electrical connection, function test and maintenance must only be carried out by

Page 35

388 - MENU ITEMS AND OPERATIONq - System congurationTo change the system conguration act as follows:• Press the “menu” button.• Scroll to "Se

Page 36

39132548 - MENU ITEMS AND OPERATIONTechnical Dept. - All rights reserved - Reproduction is prohibitedSYSTEM CONFIGURATIONSUpon installation, the produ

Page 37

4017355462137855411610928 - MENU ITEMS AND OPERATIONCONFIGURATION 2.1 (FACTORY SETTING)CONFIGURATION 2.2

Page 38

411755312481169213255171311441514768 - MENU ITEMS AND OPERATIONTechnical Dept. - All rights reserved - Reproduction is prohibitedCONFIGURATION 3CONFIG

Page 39

42155441311671416238 - MENU ITEMS AND OPERATIONCONFIGURATION 51 COMPACT2 HEATING DELIVERY3 HEATING RETURN4 ZONE VALVES5 HEATING BODIES6 DOMESTIC HOT W

Page 40

438 - MENU ITEMS AND OPERATIONTechnical Dept. - All rights reserved - Reproduction is prohibitedOPERATING MODEFlame modulation is managed according to

Page 41

448 - MENU ITEMS AND OPERATIONIMPORTANT!Set up all of the electrical and hydraulic connections to the hydraulic kit, purchased separately, following t

Page 42

459-SAFETY DEVICES AND ALARMSTechnical Dept. - All rights reserved - Reproduction is prohibitedSAFETY DEVICESThe product is supplied with the followin

Page 43

469-SAFETY DEVICES AND ALARMSTAMPERING WITH THE SAFETY DEVICES IS PROHIBITEDIf the product is NOT used as described in this instruction manual, the ma

Page 44

479-SAFETY DEVICES AND ALARMSTechnical Dept. - All rights reserved - Reproduction is prohibitedALARM ALERTSWhenever an operating condition other than

Page 45

31-WARNINGS AND WARRANTY TERMSTechnical Dept. - All rights reserved - Reproduction is prohibitedINFORMATION:Please contact the retailer or qualied pe

Page 46

489-SAFETY DEVICES AND ALARMSNORMAL SHUTDOWN (on the panel: OFF with ashing ame)If the shutdown key is pressed or if there is an alarm signal, the b

Page 47 - SAFETY DEVICES

499-SAFETY DEVICES AND ALARMSTechnical Dept. - All rights reserved - Reproduction is prohibitedSafety thermostat - Alarm A03This type of alarm occurs

Page 48

5010-MAINTENANCE AND CLEANINGDAILY OR WEEKLY CLEANING PERFORMED BY THE USERBEFORE EACH START-UPClean the ash and any deposits in the brazier that coul

Page 49

51HFGE10-MAINTENANCE AND CLEANINGTechnical Dept. - All rights reserved - Reproduction is prohibitedCLEAN THE EXCHANGER AND THE UNDERGRATE SPACE EVERY

Page 50

52FDACBIGHEVV10-MAINTENANCE AND CLEANINGPERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIANCLEANING THE EXCHANGER AND PIPE UNITCLEANING THE UPPER CO

Page 51

53S TU10-MAINTENANCE AND CLEANINGTechnical Dept. - All rights reserved - Reproduction is prohibitedATTENTION: It is advisable to carry out the cleanin

Page 52 - 10-MAINTENANCE AND CLEANING

5410-MAINTENANCE AND CLEANINGEND-OF-SEASON SHUTDOWNAt the end of season, before shutting down the boiler, we recommend completely removing pellets fro

Page 53

5510-MAINTENANCE AND CLEANINGTechnical Dept. - All rights reserved - Reproduction is prohibitedPARTS/INTERVAL 23 DAYS EVERY WEEK 15 DAYS 6090 DAYS E

Page 54

5611-PROBLEMS/CAUSES/SOLUTIONSCHECKING THE INTERNAL COMPONENTSATTENTION:GUIDE FOR THE EXCLUSIVE USE OF THE SPECIALISED TECHNICIAN.ATTENTION:All repair

Page 55

5711-PROBLEMS/CAUSES/SOLUTIONSTechnical Dept. - All rights reserved - Reproduction is prohibitedANOMALY POSSIBLE CAUSES SOLUTIONSThe boiler runs for a

Page 56

41-WARNINGS AND WARRANTY TERMSEXCLUSIONSThe guarantee does not cover malfunctions and/or damage to the appliance that arise due to the following cause

Page 57

5811-PROBLEMS/CAUSES/SOLUTIONSThe boiler does not start No power supply Check that the plug is inserted and the main switch is in the “I” position.Pel

Page 58 - 11-PROBLEMS/CAUSES/SOLUTIONS

5912-WIRING DIAGRAMTechnical Dept. - All rights reserved - Reproduction is prohibitedMOTHERBOARD WIRING KEY1. FUSE2. BOARD PHASE3. BOARD NEUTRAL4.

Page 61 - 12-WIRING DIAGRAM

REV. 1 09/04/2014Via La Croce n°833074 Vigonovo di Fontanafredda (PN) – ITALYTelephone: 0434/599599 r.a.Fax: 0434/599598Internet: www.mcz.ite-mail: in

Page 62

51-WARNINGS AND WARRANTY TERMSTechnical Dept. - All rights reserved - Reproduction is prohibitedSPARE PARTSIn the event of a malfunction, consult the

Page 63

61-WARNINGS AND WARRANTY TERMSRULES FOR INSTALLATION The product is a boiler that uses wood pellets.Below is a list of European regulations regarding

Page 64

72-INSTALLATION INSTRUCTIONSTechnical Dept. - All rights reserved - Reproduction is prohibitedThe instructions in this chapter refer explicitly to the

Comments to this Manuals

No comments